Agent Release Control Panel RP-2002(E)

Description

The RP-2002 is a six-zone FACP for single and dual hazard agent releasing applications. The RP-2002 provides reliable fire detection, signaling and protection for commercial, indus-trial and institutional buildings requiring agent-based releasing. The RP-2002 is compatible with System Sensor’s i3 detectors which are conventional smoke detectors that can transmit a maintenance trouble signal to the FACP indicating the need for cleaning and a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the control panel is compatible with conventional input devices such as two-wire smoke detectors, four-wire smoke detectors, pull stations, waterflow devices, tamper switches and other normally-open contact devices. Refer to the Notifier Device Compatibility Document for a com-plete listing of compatible devices.

Four outputs are programmable as NACs (Notification Appli-ance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble and Supervisory) and 24 VDC special application resettable and non-resettable power outputs are also included on the main circuit board. The RP-2002 supervises all wiring, AC voltage, battery charger and battery level.

Activation of a compatible smoke detector or any normally-open fire alarm initiating device will activate audible and visual signaling devices, illuminate an indicator, display alarm infor-mation on the panel’s LCD, sound the piezo sounder at the FACP, activate the FACP alarm relay and operate an optional module used to notify a remote station or initiate an auxiliary control function.

The RP-2002E offers the same features as the RP-2002 but allows connection to 220/240 VAC. Unless otherwise speci-fied, the information in this data sheet applies to both the 110/ 120 VAC and 220/240 VAC versions of the panels.

Specification

• Listed to UL Standard 864, 9th edition.
• FM Approved.
• Designed for agent releasing standards NFPA 12, 12A, 12B, and 2001.
• Meets International Building Code (IBC) seismic require-ments.
• Disable/Enable control per input zone and output zone.
• Extensive transient protection.
• Dual hazard operation.
• Adjustable pre-discharge, discharge and waterflow delay timers.
• Cross-zone (double-interlock) capability.
• Six programmable Style B (Class B) IDCs (Initiating Device Circuit).
• System Sensor i3 series detector compatible.
• Four programmable Style Y (Class B) output circuits – (spe-cial application power).

NEED TO CALL
RIGHT NOW ?

No worries, you can call one of our Salesperson:

Andree Mark

Rendy Sastrapriady

NEED TO CALL
RIGHT NOW ?

No worries, you can call one of our Salesperson:

Andree Mark

Rendy Sastrapriady

error: Content is protected !!

We are passionate about fire protection and safety. We are a growing company that offers a range of products and services to meet your needs. You can trust us to deliver quality, reliability, and innovation. We are here to help you reach your goal of a safer and more secure environment.

Get a quote

What is your concern? Let’s talk!